3KW IBC HEATER ASSEMBLY

Category:

Description

We are very proud of our 3KW IBC HEATER ASSEMBLY, fully UK manufactured, to exactingly high standards, from high quality component parts (resistance coil wire, magnesium oxide, tubing & electrical connections) assembled by highly skilled technicians & top CNC machinery. Paid proper wages to cover their unfortunately high taxes.

950mm TOTAL VERTICAL DROP

50mmØ 400mm x 78Ø VERTICAL HEATED SECTION 1 X COILED ELEMENT Centre POCKET 300×300 IP65 BOX ROTARY ISOLATOR CONTROL & LIMIT T/STAT

3KW IBC HEATER ASSEMBLY SPECIFICATIONS

Centre POCKET 400mm
300×300 IP65 PAINTED STEEL TERMINAL ENCLOSURE.
ROTARY ISOLATOR SWITCH
-5°c / +40°c CONTOL THERMOSTAT 16A SINGLE POLE
0-100°c SECONDARY LIMIT THERMOSTAT – MANUAL RESET. 16A SINGLE POLE
INDICATOR LAMPS FOR POWER, HEATING, AND RESET.
2 SUPPORT ARMS TO SECURE HEATER ASSEMBLY TO IBC FRAME
M20 CABLE GLAND

Uses

IBC’s containing liquids and ingredients that become less viscous and difficult to handle at low temperatures.

Low Watt Density

Element operates at 18 watts per inch² (2.80 watts per cm²). Suitable for many liquids.
Check with liquid producer before application of direct heat for special considerations particular to the material to be heated.

Construction

Incoloy heating element formed to coil for efficient heat transfer at low level within IBC
316 Stainless Steel Non-Heated Vertical Conduit
Alloy 800 or AISI316 Thermostat Pocket
Stainless Steel IBC Cap cover – loose fit to prevent contamination.
300x300x120 Coated Steel IP65 Terminal Enclosure

Dimensions

950mm Vertical Drop (Height)

450 Heated Section 78mm Diameter

300x300x120mm IP65 Terminal Enclosure Steel powder Coated

2 x 1000mm Support Rails Galvanised Steel

Controls

Integrated Multi-pole Isolator switch with Lock-out facility to prevent operation when out of IBC.

Power, Heating, and Reset indicator lamps.

Control Thermostat -5°c to +40°c Auto Reset, 16A Single Pole – 1000mm Capillary Length

Secondary Hi-Limit Thermal shut off device Adjustable set point 0-100°c. Requires manual reset.

 

Please use our heating calculators to figure out your kW needs. Bear in mind 6kW is the maximum you can squeeze onto a Single Phase. That will require 32 amp everything.